Dealers
tabs
Power/Filter Slide
Diagonal Binoviewer System
PFS-D


SCT Instructions             Refractor Instructions            Dioptor Instructions




“ALL IN ONE”
POWER/FILTER SLIDE
  DIAGONAL BINOVIEWER
SYSTEM FOR SCT’s & REFRACTORS  

PFS-B

SYSTEM FEATURES:
26 MM CLEAR APERTURE BINOVIEWER /DIOPTORS
          
"ALL IN ONE" POWER/FILTER SLIDE CORRECTOR SYSTEM
              
SILVER ENHANCED DIAGONAL

BLACK PLASTIC CASE WITH DIE CUT FOAM  TOTAL SYSTEM WEIGHT: 50.5 oz


INSTRUCTIONS FOR POWER/FILTER SLIDE DIAGONAL SCT
PFS-D

Load the Power/Filter Slide Diagonal Binoviewer System into your SCT telescope visual back or focuser and tighten securely.  You are now ready to Power/Filter Slide.

 
Back to Top
Back to Products


INSTRUCTIONS FOR POWER SLIDE

Focal Reduction - .52-  Push thumb tab 1 to the center position (Fig. B) and bring to focus. 

PFS-D

Normal Power – 1.1X- Thumb tab 1 in Left position---Thumb tab 2 in right position, Fig C and bring to focus.

PFS-D

High Power - 1.5X- Thumb tab 2 pushed to center position, Fig D and bring to focus

PFS-D
 
Back to Top
Back to Products


FILTER/SLIDE INSTRUCTIONS

The EarthWin Optical Power/ Filter Slide includes two empty filter cells which can be loaded with 2’’ filters by the user. Filters are held in place by a non-marring nylon tipped set screw and tightened with a supplied hex wrench. The Filter Cells can be loaded or easily withdrawn from the housing and replaced by different cells in a matter of seconds.  Extra 2” filter cells and 1 1/4” adapter cells can be purchased separately and come in square plastic filter cases.  The Filter Slide is independent of the Power Slide so filters can be introduced at any time.     


Step 1 - Using the thumb tabs (3 & 4),pull both holders out of the Filter Slide. Insert your filters and seat to the bottom of the holder.  Tighten set screws firmly to hold the filter in.
Step 2 - Re-insert the filter holders into the slide (filter holders are marked “L” and “R” on top corners).  You are now ready to Filter Slide.  Use thumb tabs 3 and 4 to introduce desired filters. See Fig. E
PFS-D
 
Back to Top
Back to Products


INSTRUCTIONS FOR POWER/FILTER SLIDE DIAGONAL REFRACTOR
PFS-D

Load the Power/Filter Slide Diagonal Binoviewer System into your Refractor telescope  focuser and tighten securely.  You are now ready to Power/Filter Slide.

 
Back to Top
Back to Products


INSTRUCTION FOR POWER SLIDE

Low Power - 1.3X -  Push thumb tab 1 to the center position (Fig. B) and bring to focus. 

PFS-D

Med. Power - 1.9X- Thumb tab 1 in Left position---Thumb tab 2 in right position, Fig C and bring to focus.

PFS-D

High Power – 2.5X - Thumb tab 2 pushed to center position, Fig D and bring to focus.

PFS-D
 
Back to Top
Back to Products


FILTER/SLIDE INSTRUCTIONS

The EarthWin Optical Power/Filter Slide includes two empty filter cells which can be loaded with 2’’ filters by the user. Filters are held in place by a non-marring nylon tipped set screw and tightened with a supplied hex wrench. The filter's cells can be loaded or easily withdrawn from the housing and replaced by different cells in a matter of seconds.  Extra 2” filter cells and 1 1/4” adapter cells can be purchased separately and come in square plastic filter cases.  The Filter Slide is independent of the Power Slide so filters can be introduced at any time.    


Step 1 - Using the thumb tabs (3 & 4),pull both holders out of the Filter Slide. Insert your filters and seat to the bottom of the holder.  Tighten set screws firmly to hold the filter in.
Step 2 - Re-insert the filter holders into the slide (filter holders are marked “L” and “R” on top corners).  You are now ready to Filter Slide.  Fig. E shows no filter in the light path. Figure F and G show filters pushed into position.
PFS-D PFS-D PFS-D
 
Back to Top
Back to Products


DIOPTER INSTRUCTIONS
Eyepiece Loading Procedure

Our Dioptors are a non-marring split ring design that centers and locks the eyepiece as the user tightens the top knurled ring.  To load an eyepiece simply hold the bottom knurl firmly with one hand and rotate the top black knurled ring counter-clockwise to loosen enough to recieve an eyepiece. Once the eyepiece is inserted,again hold the bottom knurl firmly and rotate the top black knurled ring clockwise until eyepiece is firmly tightened.  Now, with eyepiece locked into place, both rings can be used to dioptor.

 
Diopter Adjustment
Dioptor adjustment can be done in several ways depending on the user's preference. After adjusting the dioptors a couple of times the user will develop the preferred method for his or her eyes. Ideally, the end result is to have both eyes in sharp focus without over-extending the dioptors. This helps keep the light path shorter and maintains accuracy of the dioptor.
 
Instructions

Start with the dioptors rotated all the way down(clock-wise). Use the procedure to load the eyepieces into the holders. Now rotate the each dioptor 1/2 turn counter-clockwise. This will be the starting point to focus the binoviewer system with the telescope focuser. When close focus is achieved, fine tune each eye individually using the dioptors by rotating positive or negative. Take notice of the final position of the dioptors while system is in focus. This will help you in developing your own method of adjustment. 

 
Back to Top
Back to Products


Copyright © 2008-2009
Home Products Special Promotions Dealers About UsContact Us Home Home